Greenovoc

Finguard

High-Performance Coating for HVAC Coils & Heat Exchangers

FINGUARD is a single-pack, water-based, sustainable high-performance coating formulated using patented Grafted Co-Polymer Technology.

It is specifically engineered for HVAC coils, fins, condensers, and radiator systems to deliver superior corrosion protection without compromising heat transfer efficiency.

Key Features & Benefits

  • Excellent corrosion resistance

  • Quick drying performance

  • Superior heat transfer efficiency

  • Excellent resistance to acids (up to 20%)

  • Excellent resistance to alkalis (up to 20%)

  • Resistance to corrosive gases

  • Outstanding outdoor durability and stability

  • Environmentally responsible water-based formulation

Recommended Usage

It is recommended for:

  • Ferrous and non-ferrous HVAC coils

  • Aluminium fins

  • Copper coils

  • Condenser tubes and fins

  • Radiator systems

The coating provides effective protection against:

  • Moisture

  • Industrial pollutants

  • Chemical exposure

  • Condensate formation

  • Aggressive operating environments

Additionally, it delivers a uniform and aesthetically pleasing finish.

Film Thickness & Coverage

  • Recommended Dry Film Thickness (DFT):
    10–15 microns per coat
    Recommended system: 2 coats

    Theoretical Coverage:
    Approximately 8 m² per kg per coat
    (Coverage may vary depending on surface profile and application method.)

Surface Preparation

ParameterRequirement
Surface CleanlinessSurface must be clean and dry
Contaminant RemovalFree from oil, grease, dust, and other contaminants
Standard ReferenceSurface preparation to be carried out as per ISO 8504

Surface Conditions for Application

ParameterRequirement
Substrate TemperatureMinimum 3°C above dew point of ambient air temperature
Relative HumidityMaximum 80% (measured near substrate surface)

Performance Properties

Sr. No.Test DescriptionStandardResult
1Scratch Hardness (3.5 kg)ASTM D7027No exposure of metal substrate (Pass)
2Conical Mandrel (4 mm)ASTM D522No film cracking or crazing
3AdhesionASTM D3359No peel-off
4Salt Spray Resistance – 1000 hrs (at 30 µm DFT)ASTM B117No surface deterioration or corrosion
5Thermal Stability at 200°C for 24 hrsASTM D2243No effect on coating surface
6SO₂ Moisture ResistanceASTM G87No effect on coating surface

Application Method

ParameterDetails
Application EquipmentAir-assisted spray equipment recommended
PurposeEnsures uniform coating thickness and optimal performance

Application Data

ParameterDetails
Mixing RatioSingle-pack system – No mixing required
Pot LifeNot applicable
ReusabilityMaterial can be reused if container is properly sealed and stored within shelf life

Drying Time

General Information
ParameterDetails
Influencing FactorsAir circulation, substrate temperature, film thickness, number of coats
Minimum Recoat Time30 minutes
Hard Dry24 hours
Full CureMinimum 24 hours for full performance properties
Typical Drying Times (Well-Ventilated Conditions)
Substrate TemperatureSurface Dry (Dry to Handle)
-10°C30 minutes
0°C25 minutes
10°C20 minutes
23°C15 minutes
40°C10 minutes

Typical Paint System

ProductSystem Specification
FINGUARD2 coats × 10–15 µm Dry Film Thickness (DFT) per coat

Storage

ParameterRequirement
Storage ConditionsAs per applicable national regulations
EnvironmentCool, dry, well-ventilated area
SafetyKeep away from heat, sparks, and ignition sources
Container HandlingKeep containers tightly closed when not in use

Shelf Life

ParameterDetails
Storage TemperatureBelow 25°C
Shelf Life6 months from date of manufacture (under recommended storage conditions)

Handling Instructions

InstructionRequirement
StirringStir thoroughly before use
Container HandlingHandle with care
After UseReseal immediately after use
PrecautionAvoid contamination and prolonged air exposure

Packaging

Available Pack Sizes
5 kg plastic pails
10 kg plastic pails
20 kg plastic pails

Disclaimer :

The information in this Technical Data Sheet is based on laboratory testing and practical experience and is provided to the best of our knowledge.

As product application conditions are beyond our control, no guarantee or warranty, expressed or implied, is provided regarding suitability for a particular purpose, other than the quality of the product supplied.

Users are responsible for determining product suitability for their specific application.

Greenovoc Specialty Coatings Pvt. Ltd. reserves the right to modify specifications without prior notice to meet regulatory or performance requirements.

Featured

Most popular questions

FINGUARD is a single-pack, water-based, high-performance protective coating designed specifically for HVAC coils, fins, condensers, and heat exchangers. It provides superior corrosion protection while maintaining excellent heat transfer efficiency.

FINGUARD is suitable for:

  • Aluminium fins

  • Copper coils

  • Ferrous and non-ferrous metals

  • Condenser coils

  • Radiator systems

  • HVAC heat exchangers

It is designed for use in both indoor and outdoor environments.

No. FINGUARD is engineered to provide corrosion protection without compromising heat transfer efficiency. The recommended thin film thickness (10–15 microns per coat) ensures optimal thermal performance.

FINGUARD protects against:

  • Corrosion

  • Moisture and condensate

  • Industrial pollutants

  • Chemical exposure (acids and alkalis up to 20%)

  • Corrosive gases

  • Salt spray environments

Yes. FINGUARD offers excellent resistance to acids and alkalis (up to 20%), along with resistance to SO₂ moisture exposure and corrosive gases.